in my code,im inputting a byte coming from Arduino board microncontroller..im sending character 'N' to com5, and the code above is fetching that data from arduino board..my problem is the output string on the textbox is <78> which is the ASCII equivalent of 'N' how will i convert that to what is really being sent by the board which is 'N'..
I am using serial port class from VB.net to communicate my hardware. Some times I may lost or get incorrect data. I am just wondering how to implement hardware flow control in Vb.net
i'm creating a windows form to send/receive data to/from serial port.At first : i send the data as string to the serial port .Second: i tried to read the string again for test the successfull transmission , but i recieved empty string
I have a device that communicates with the pc via a serial to usb cable. So I have made windows form with a serial communication to speak with it. The communication is every 125ms so every time it checks if the com port is open and sends the new message. The problem is that if the usb is not connected the program tries every 125 ms to connect to the serial port and the busy cursor appears always and the form is not responding to any action (for example enter into the menu or refresh a listbox). I have tried multiple times to connect and disconnect the usb while the program is running. That's mean that the serial connection stopped and started all over again several time. The problem is that occasionally it shows an error "unable to open com port".
What is the best way of communicating with Serial ports and TCP/IP communcation using vb.net?Using visual studio .net can we make it easier?? Can anyone send me sample application of communications?If I write a program communicating with my hardware using Searial port or TCP/IP, will the program be slow?? Are there any programming techniques working with communication ports?
I want to perform serial communication on selecting .Net Framework2.0--->Visual Basic--->Device application
Presently I am using this code Imports System.IO.Ports Imports System.IO.Ports.Serialport If Button1.Text Is "open port" then SerialPort1.Open() Button1.Text="close port" Button2.Enabled=True [Code] .....
But I am getting error as "An unhandled exception of type System.InvalidOperationException occurred in System.dll Additional Information: The basestream is only available when the port is open".
I am using two serial port in my programm.What is want is, i need to receive data from one port and send on another port and vice a versa.This code receive data from one port but can't receive data from another port. I have tried to simulate this code by using hyper terminal and it works properly with both com port. Where as i have written code in Vb6 too and its is giving same problem as giving interupt while recieved data from one port but not giving interupt which receiving from another port. I know the another way to receive data is by using timer and read data by command as readline(), but what to do to make both the port gives interupt which receive data.Please help to find out the porblem, the code is in Vb.net and it is as under.[code]
I want to communicate Weigh bridge with my ORACLE Form serially. I have already import MSCOMM32.OCX in my Project and On Button Pressed I wrote a Program to Start Communication between Weigh Bridge and my form. I was stuck at GET_NUM_PROPERTY of MSCOMM32.OCX Package.
I am trying to get serial port communication working between two PC's.
My environment is: XP SP3, 9 pin serial ports on both ends, connected by a null modem cable, Visual Basic 2010 Express.
I have a sending routine and a receiving routine, both based on the on line documentation.
There are no Errors, Warnings or messages.
Problem: The receiving machine shows no sign of receiving a message sent by the sending PC. I have tried making the sending PC into the receiving PC - makes no difference.
My sending routine looks like this:
Sub SendSerialData(ByVal SendData As String) 'Send string to serial port Using com1 As IO.Ports.SerialPort = My.Computer.Ports.OpenSerialPort("COM1", 9600, Parity.None, 8, StopBits.One)
when I connected the program with a serial port and planning to get the data from the serial port to the label, the label was error its says Cross-thread operation not valid: Control 'Label1' accessed from a thread other than the thread it was created on.
[Code]...
is there any limitation for data taken from serial connection??
I want to take a number such as 600 (0x0258) and send these hex values to a C-based system which is assigning char's to the received bytes and rebuilding to the original number. Currently, I am converting to bytes in VB.Net but it is not giving me the expected outcome (because of the ascii nature of the transfer most likely) [Code] I've also tried using Hex but this doesn't get the data in the correct format.
as i learn VB 2010 express, i want to try some serial communication and i found this code for VB6..but i have no idea how to make it work in VB2010?
Private Sub Form_Load() MSComm1.RThreshold = 44 'transfer data into VB program only after receiving 44 characters into buffer MSComm1.InputLen = 0 'i think only for receive data & not for sending data ...check MSComm1.CommPort = 1
I am trying to interface an instrument that I send orders to.An order consists of 4 lines which I am to write to the serial port one at a time and receive an ACK before sending the next line.I have interfaced in the past using the MSCOMM, I'm new to the Serial Port class. But even then I've always received data, never sent anything.My question is when I'm looping through my 4 lines of my order, at what point do I receive ACK? Obviously, not in the same function, right? And how do I know I received an ACK and can go on to output the next line?
I implemented a serial communication between a PC and a circuit based on ATMEL mP, managing the submission of correct / incorrect reception of commands ... The following code works, I wanted a block on the performance and reliability as it is for me very important part of this project that I'm doing.
Public Class frmTrattamento Dim IsStart As Boolean = False Dim inputData As String = "" Dim Stmp As String = "" Public Event DataReceived As IO.Ports.SerialDataReceivedEventHandler [Code] .....
I'm trying to read data coming from a serial port. I simply want to ignore all other data besides the string "button_pushed". The device actually writes "button_pushed" to clean up the display when viewing the serial connection from console or similar. I can change this easily but I'd like to keep it if possible.
My code is as follows:
[Code]...
I'll get an IOException from readLine(). I tried using readExisting() which prevented the error but results in the block being executed twice (probably caused by the "") so the log reads "No data match" and "Data match" for one button push.I have a few questions. First, why does ReadLine cause an exception? I tried to negate that with is_closing but it still occurs. Second, will I run into problems using readExisting as it reads the entire buffer?
I have a gps logger which store the gps data into its internal memory .I have a description file for the data format and how to send commands to the logger to get data . this file is present at the following website L [URL]
I need to make a vb.net application that can download data from the gps logger . and to set its configuration parameters .
I am working on an application on serial port communication with PLC machine. Now this communication is only done with one PLC at a time. So I m sending a query to PLC and until its responds back the application goes into wait mode. i.e. no other operations can be done, and an hourglass cursor should be displayed with all other components locked on the form. So how do I achieve this using vb.net?
I am having some issues with serial port communication. My event handler to poll data is not working. I even tried to retrieve it using a button event, but that also does not work. I know there is data in the buffer.Here's my
Private Sub DataReceived( _ ByVal sender As Object, _ ByVal e As System.IO.Ports.SerialDataReceivedEventArgs)[code]...........
Using Visaul Basic 208 Express. I have running serial port communications with send and receive texts shown in a richtext box. I would like to store that data in a text file for later review.reate such window text file to store all data sent and received from the serial port in all events. I would like to have that file accessible through a button in the form. Also, the file should store all data in all events, i.e. same file needs to be opened so all data accumulated in all events
I am using two computer to connect to each other via serial port, I have made a program in VB that allows me to read from the serial port then store whatever that character is to a variable. The only problem is I have to hit a button to read in from the serial port and pass the character to the variable. Is there any way to do this automatically?
I've seen this great example of serial communication in VB.NET
[URL]
I try to use it in a project I am working on but somethings are not clear to me.
1: Now the send and received data is shown in one RichTextBox but I would like to split this into two RichTextBoxes (RtbSend and RtbReceived).It is unclear to me how and were data is assigned to the RichTextBox?
2. the received data is shown in the Richtextbox as one long line, I would like to get a new line for every send message.So for example: I I send "test" four times, I would like to see:
Test Test Test Test
now I see: Test Test Test Test I've tried ctrlf but this does not work.The example describes that "comPort_DataReceived" is executed when data is waiting in the buffer. Where can I see the eventhandler responsible for this? How does it know data is waiting?The problem is this kind of coding is a bit to difficult for me. I want to understand the code before I implement it into my project.
I am trying to create a client server application. I am going to make this simple so that a basic chat application. I have gone through these tutorials:
I have a VB2005 application that sends and recieves data with another application (3rd party, not vb 2005) via COM port. When I run the apps on different computers they work great, they send all data to eachother and everything is fine. When I run them both on the same computer with either virtual null modem ports or with 2 hardware ports connected together via null modem cable they stop communicating.
In my application I am using MSComm32.ocx control for the purpose of serial port communication. when i am using it I am getting a following error while writing data to the port.
"AxMSComm1.Output {"Exception from HRESULT: 0x800A018A (CTL_E_GETNOTSUPPORTED)"} Object "
I am writing the output to the port like below. AxMSComm1.Output ="Hello"
I mention the properties of the ocx control in the form load like below. AxMSComm1.CommPort = 1