What i get from minfo.invoke i am binding to the grid gv1 !!! But unfortunately its not working for all minfo !!!! Few errors are like : return type is not IListSource ,IEnumerable or IDataSource !!!!
returns IEnumerable or IData Source or IListSource !how to do that ?Also if return type is none of these i should display the result in a Textfield by Serializing the data and displaying it as an XML?How to do that too?
I have an interface ITest with a method GetResult(). I have a class Test which implements ITest and thereby defines private method GetResult().
Next I create an instance of Test in a different class. The code is as below:
Module NewClass Public Sub New() Dim i As ITest = New Test()
[Code]....
I am migrating existing code from VB 6 to VB.NET and hence I'm not supposed to change the access modifier of GetResult. Leaving it Private will throw InvalidCastException Unable to cast object of type 'System.Object' to type 'ITest'
Object type variable o is used in many places and hence I don't want to change that. And yes, Test implements ITest.GetMember with a different name.
I want to invoke the Interface IFileOperation using VB.NET in Windows 7, delete files or directories locate on different paths to Recycle Bin once, and show the Windows deleting UI, but do not know how to start the Interface IFileOperation
I have been using a pretty slick generic invoke method for UI updating from background threads. I forget where I copied it from (converted it to VB.NET from C#), but here it is: Public Sub InvokeControl(Of T As Control)(ByVal Control As t, ByVal Action As Action(Of t))
1. On the main form a scanner class is instantiated that (in the scanner's constructor) sets the scanner settings (baud rate, parity, etc) and opens the scanner for use
2. A barcode is scanned (via a scanner connected to the device in a seral port) while on the main form
3. In the scanner class, the DataRecieved event gets the needed info from the scanned code.
4. Then that info is passed back to the main form to a method RunCommandCode (which takes the scanned info as an argument)
5. On the main form the RunCommandCode calls another method CommandCodeHandler, passing the scanned info again
6. In the CommandCodeHandler sub a method is called in a Utils class (SetSelectedTab), which interacts with the form itself (determines how many tabs exist on a tab control), which is the reason for the invoke in the first place
So, before I figured out I needed to use the Invoke method (and, more specifically, that the scanner was working in a different thread), I was getting an error in step 6 on the line that got the TabControl.TabPages.Count.
I am implementing a custom iDispatchLLInvoke handler for VB.NET - some of this is working.So Far - I have been able to intercept and provide custom handling of simple functions and property calls - but I am stuck when I try to set a property and get an error "Invalid Pointer (Exception from HRESULT: 0x80004003 (E_Pointer))".
I am using the new .NET 4.0 ICustomQueryInterface to do this. In Summary - I intercept and provide my own implementation of iDispatch - I load the dispIDs on the first call - and return a the dispID for each call within GetIDsOfNames - this ID is than passed to Invoke where reflection is used to get the value and return the result.
When I attempt to set a property - a call is made to GetIDsofNames and I return a valid dispID - the application than crashes with the error above and no call is made to Invoke.As a result - I am assuming that the issue relates to my interface definition been wrong becase the code never get's back to .NET code - see below for this code:
<ComImport(), Guid("00020400-0000-0000-C000-000000000046"), InterfaceTypeAttribute(ComInterfaceType.InterfaceIsIUnknown)> _ Public Interface IDispatch Sub GetTypeInfoCount(ByRef pctInfo As UInt32)
I've created a MyFunc extension (in Module Extensions) for all the base types as well as generic arrays, ICollection(Of T) and Dictionary(Of String,T):
Function MyFunc(Of T)(a() As T) As String Function MyFunc(Of T)(collection As ICollection(Of T)) As String Function MyFunc(Of T)(dict As Dictionary(Of String,T)) As String
I want to invoke a method on a class that i have a reference to. The method that I want to call has a custom attributes. Currently I can find this attributes and call the property of my class Attribute.
is there a way to invoke that method ?
PS/ The project is written in vbnet, but I think the solution is the same in c#.
Is it possible to somehow invoke foo("SomeAwesomeString") from VBScript directly (i.e., without it having to launch an additional process)?
The use case is this: I am trying to write an 'extension' application for hMailServer (hMS), but hMS can only invoke VBscript scripts when an event happened. I can have the VBscript launch an .exe every time the event happened, but the processing involve opening and closing a connection to a back-end database. So, every invocation is very expensive. I had been thinking that I can reduce the expense by having a Service to maintain the connection (i.e., opening it once and re-open it if the connection closed). Plus by implementing the processing as background worker threads will result in a non-blocking processing + less process-starting overhead.
I have a COM component that I want to call using late-binding from VB.NET (using Primary Interop Assembly - PIA method). My IDL signature for the COM method looks like: HRESULT Send([in]BSTR bstrRequestData, [out]VARIANT *pvbstrResponseData, [out]VARIANT *pvnExtCompCode, [out,retval]int *pnCompletionCode);
So 2 'ByRef' parameters in VB.NET lingo, and a return value. I attempt to invoke this method like so: Dim parameters(2) As Object parameters(0) = "data" parameters(1) = New Object() parameters(2) = New Object() Dim p As New ParameterModifier(3) [Code] ..... This fails spectactularly with an exception: {"Invalid callee. (Exception from HRESULT: 0x80020010 (DISP_E_BADCALLEE))"}
I assume this means I'm doing something wrong in my parameterMods array. Because if I comment out setting any value of the ParameterMods array to 'True' - it works. It of course doesnt update the parameters that are [out] parameters and so it's not working as intended. Is there something else to consider since the method also has a return value? The MSDN example pretty much does exactly what I am doing, with the exception that example did not have a return value.
I Have a Function on my frmMain Class wich will update my control to something else after an invoke. When i type "?Label1.Text" on the Immediate Window, the text property IS updated, but when i go check the Form, nothing happened. The code is just like this
I have a ASP.NET (C#) web page which utilizes a VB class library. The VB library performs a SOAP POST to a remote web service and returns a message. However the VB library keeps running into a "No connection could be made because the target machine actively refused it xxx.xxx.xxx.xxx" However, I've also created a C# test client which consumes the same VB class library and can perform the post just fine! [code]
The problem is that, when I call the "SetStatusBarText" sub from another thread, InvokeRequired is True (as it should be), but then my threads stall on the Me.Invoke statement - pausing execution shows them all just sitting there, not actually invoking anything.
I am building a software which will be used to create a remote desktop connection. However I'm getting this error:
Unable to cast COM object of type 'System.__ComObject' to interface type 'MSTSCLib.IMsTscNonScriptable'. This operation failed because the QueryInterface call on the COM component for the interface with IID '{C1E6743A-41C1-4A74-832A-0DD06C1C7A0E}' failed due to the following error: Δεν υποστηρίζεται τέτοια διασύνδεση (Exception from HRESULT: 0x80004002 E_NOINTERFACE)).
public delegate UsernameCredentials UsernameRequiredEventHandler( object sender, string endpoint ); public event UsernameRequiredEventHandler UsernameRequired;
On Converting the above code in VB.Net as follow :
Public Delegate Function UsernameRequiredEventHandler(ByVal sender As Object, ByVal endpoint As String) As UsernameCredentials Public Event UsernameRequired As UsernameRequiredEventHandler
I am getting error on the above line saying that "Events cannot be declared with a delegate type that has a return type".I understand that this is not supported in VB.Net.
In trying to add a bit of usage variety to a generic class I'm working on, I ran into this issue with trying to cast an object into an interface instance where the interface is defined inside the generic class.
I have been trying to use vb2008 to automatically update CustomDocumentProperties fields that I have set up within a pro-forma document. I can load the Word application and word document without problems.I want to update the CustomDocumentProperties fields with data read from a dB. To do this I am assuming that I need to iterate through the CustomDocumentProperties fields within the word document and when one is "found" that matches the data I wish to merge then assign the dB value to the field.The problem is that I am getting an exception error when I try to reference the document customdocumentproperties
"Error : Unable to cast the COM object of type 'System._ComObject' to interface type 'Microsoft.Office.Interop.Word.CustomProperties'. ...... "
my code looks like;
Dim WordApp As Word._Application Dim odoc As Word._Document Dim BContinue As Boolean = True
Public Class CalculationParameter{ public Long TariffId{get;set;} }
In a workflow activity, I've an Assign like this:
(From tariffDetail In db.Context.TariffDetails Where tariffDetial.TariffId = calculationParameter.TariffId).FirstOrDefault()
Dto is passed to Activity as an Input Argument.It raise following error and I'm wondering how to assign Id.LINQ to Entities does not recognize the method 'Int64
GetValue[Int64](System.Activities.LocationReference)' method, and this method cannot be translated into a store expression.
How can I assign the calculationParameter.TariffId to tariffDetial.TariffId?!
UPDATE:Screen shot attached shows that how I'm trying to assign calculationParameter.TariffId to tariffDetail.TariffId (car.Id = Dto.Id) and the query result should assign to CurrentTrafficDetail object.
I've run into a bit of a problem.. I am unsure as to how many people know how "IRC" Servers work here but basically, i'll explain. We are re-creating an IRC Client we made for our Chat site in VB.NET originally vb6. We have serveral different forms but the main problme we are having at the moment is FrmMain is where you login to the servers, it grabs your data from our MySQL database such as "Nick, Gender, Font" etc. Then proceeds with connection to IRC server on Raw 001 we know the connection to the IRC server has been established... so therefore we open up FrmAuth which in this case they can see roomlist etc. We are unable to get FrmAuth to load probably.
We originally had this working opening up FrmAuth before the connection to IRC server has been established.. This really is no good for us causes alot of errors etc. So when we use just simply "me.show()" the form loads but freezes we tried doing Me.Invoke(New Del(AddressOf me.show))
however, this didnt work in which I assume that is because the "FrmAuth" hasn't yet loaded the GUI thread therefore there is no Thread to invoke so we tried FrmMain.Invoke(New Del(AddressOf me.show))
This didn't work either i assume you cannot access another forms Invoke method? we are receiving the error A first chance exception of type.'System.InvalidOperationException' occurred in System.Windows.Forms.dll which i assume has something to do with it but not quite sure..
So my question comes down to the fact of, how do we open up FrmAuth without it freezing? Is there a way to access the invoke method on another form?
We are re-creating an IRC Client we made for our Chat site in VB.NET originally vb6
We have serveral different forms but the main problme we are having at the moment is
FrmMain is where you login to the servers, it grabs your data from our MySQL database such as "Nick, Gender, Font" etc. Then proceeds with connection to IRC server on Raw 001 we know the connection to the IRC server has been established... so therefore we open up FrmAuth which in this case they can see roomlist etc. We are unable to get FrmAuth to load probably.
We originally had this working opening up FrmAuth before the connection to IRC server has been established.. This really is no good for us causes alot of errors etc.
So when we use just simply "me.show()" the form loads but freezes we tried doing
Me.Invoke(New Del(AddressOf me.show))
however, this didnt work in which I assume that is because the "FrmAuth" hasn't yet loaded the GUI thread therefore there is no Thread to invoke so we tried
FrmMain.Invoke(New Del(AddressOf me.show)) This didn't work either i assume you cannot access another forms Invoke method..?? we are receiving the error A first chance exception of type 'System.InvalidOperationException' occurred in System.Windows.Forms.dll which i assume has something to do with it but not quite sure..
So my question comes down to the fact of, how do we open up FrmAuth without it freezing? Is there a way to access the invoke method on another form?
I've got an interface inheritance issue that has been vexing me for some time. It doesn't seem to make any sense, and I can only conclude that I'm missing something fundamental.
Overview The code below is from part of a fluent interface for our ORM tool. It provides a SQL-like syntax for pulling data from the database. You don't have to completely grok all the interrelations to understand the problem -- the real issue is the EndClause method.
The EndClause Issue There's a method called EndClause that doesn't show up in one expected spot -- IOrderQueryRoot. As far as I know, it should show up because it inherits from two different interfaces that both have a method called EndClause, but when I consume an object that implements IOrderQueryRoot, EndClause does not pop up in intellisense.
There are some more implementation details below.First though, if you look at IOrderQueryRoot (which contains EndClause), you can see that it inherits IHasOrderLogicalOperators, and also IHasOrderFields (which also contains EndClause).
Public Interface IHasOrderLogicalOperators Function [And]() As IHasOrderFields Function [AndNot]() As IHasOrderFields
[code]....
At this point, the interface is working fine -- if I were to remove this method, VS would scream that I have to implement both EndClause methods. The problem is one level down, when the "end developer" is trying to actually write code against the interface.