All Of A Sudden - Sql Server Timeout

May 25, 2010

We got a legacy vb.net applicaction that was working for years. But all of a sudden it stops working yesterday and gives sql server timeout.

Most part of application gives time out error , one part for example is below code :

CODE:

It was working and now gives time out in command3.ExecuteNonQuery()

Some information : There isnt anything that has been changed on network and the app uses local database. The main issue is that even in development environment it donest work anymore

View 13 Replies


ADVERTISEMENT

Error - Timeout Expired - The Timeout Period Elapsed Prior To Completion Of The Operation Or The Server Is Not Responding

May 3, 2011

I'm not sure if this is a VB.NET error or SQL Server. But I get the above error with following stack trace:

[SqlException (0x80131904): Timeout
expired. The timeout period elapsed
prior to completion of the operation
or the server is not responding.]
System.Data.SqlClient.SqlConnection.OnError(SqlException

[code]....

View 3 Replies

Set The Timeout For The Execution Of A Set Of Statements When Using The SQL Server SMO Libraries?

Jul 25, 2011

I have the following bit of code that is timing out when I pass it a long running set of SQL statements. I'm using the Microsoft.SqlServer.Management.Smo library from SQL Server 2008.

Using cn As SqlConnection = GetConnection(_destinationCNS, True)
Dim smoServer As New Microsoft.SqlServer.Management.Smo.Server(New ServerConnection(cn))

[Code]....

I'm having trouble figuring out where to declare that timeout duration. What object and property should I be setting the timeout duration for the statement execution, not the connection timeout. On the SQLCommand object there is a convenient CommandTimeout property but I'm not seeing anything like that here.

View 1 Replies

Sql Server - Provider Factory Command Timeout - How To Set It

Feb 4, 2011

I am having a problem with a SQL server query giving a timeout error. I read about setting the timeout value of the command object but in my DAL, I do not see how to do that. Here is how I create the command object

Public Sub Init()
If ConnString = "" Then
Select Case ConnStringID

[Code]....

View 1 Replies

Getting An Error While Fetching The Records From Sql Server To Datagridview - Timeout Expired

Jun 8, 2011

I am getting an error while fetching the records from sql server to datagridview. Ex. I have 10 rows in datagridview first five are with one table and next five for another table. When loop goes for next table it throws an error like "timeout expired. the timeout period elapsed prior to completion of the operation or the server is not responding. The statement has been terminated."

for (int h = 0; h <= dtgqueformat.RowCount - 2; h++)
{
string avl_subject = dtgqueformat[8, h].Value.ToString();
string avl_chapter = dtgqueformat[9, h].Value.ToString();

[code]....

View 5 Replies

Connection Leaking Causing 'System.Data.SqlClient.SqlException: Timeout Expired' Error In SQL Server?

May 19, 2010

My application requires a user to log in and allows them to edit a list of things. However, it seems that if the same user always logs in and out and edits the list, this user will run into a "System.Data.SqlClient.SqlException: Timeout expired." error. I've read a comment about it possibly caused by uncommitted transactions. And I do have one going in the application.

[Code]...

View 4 Replies

Combobox Sudden And Undefinable Exception?

Apr 7, 2010

for some reasons suddenly all comboboxes within my project An exception (System.NullReferenceException) is thrown whenever I try to scroll down a DropDown or a DropDownList to the very end. This happens to all comboboxes with more items than the MaxDropDownItems property with a vertical scroll bar. No code is being executed at the moment the exception is thrown. The application is just waiting for the user to complete his entries.

This did not happen until today and I didn't change no code. There are lot of comboboxes within the project and I'm very amazed (actually frustrated) about the exception .

[Code]...

View 14 Replies

Wpf - Baffling Sudden Error On Loading Data Table?

Jan 18, 2011

I'm using VB.net and WPF 4, as well as an SQL database.

I have been using this EXACT code successfully for several days now, with absolutely no problems whatsoever. However, now, suddenly, it is throwing the weirdest exception...

Public Class ROSTER
Dim table_adapter As New AGENT_ROSTERTableAdapters.AGENTROSTERTableAdapter
Dim roster_table As New AGENT_ROSTER.AGENT_ROSTERDataTable

[Code]....

View 3 Replies

"The Timeout Period Elapsed Prior To Completion Of The Operation Or The Server Is Not Responding"

Feb 23, 2009

"Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding." why i am getting this error message in the loop for the first row its works perfect but when it goes next in the loop and then it call again the function chkexist it gives the massege same error on call the nxtno function

[Code]...

View 3 Replies

DB/Reporting :: Tables Removed - Encountering A Sudden Loss Of Table In Database

Apr 26, 2008

For the past 3 weeks now, we are encountering a sudden loss of table in our database, but with that. our .mdf file is still on its same size before this disaster comes along and again..anyone had encountered or know how to solve this problem.

View 3 Replies

.net SQL Connection Timeout?

Apr 19, 2009

I have written some code (VB.net) which simply runs a backup on all required servers and databases in a loop. The code works perfectly, except for the first backup which Timeout's after 30 seconds (even with my Connect Timeout=0).

Everything is written manually for the dataconnection, the connection opens and timeouts on SQLComm.ExecuteNonQuery()

dbConnStr= Data Source='Server';Initial Catalog='Database';Integrated Security=False;User ID=sa;Connect Timeout=0;User Instance=False

[Code]...

View 3 Replies

No Timeout For Serialport?

Dec 16, 2011

I am using VB 2005 and need to trap a serial port timeout. I use a standard try/catch block, but if no characters arrive the code still hangs at the ReadByte call. Here is the code:

Try
SerialPort.ReadTimeout = 200
' read timeout of 200 mSecs
thisByte = SerialPort.ReadByte()

[code]....

View 5 Replies

Session Timeout In ASP.NET

Jun 7, 2010

I have written a page with an iFrame that basically cycles through a series of internal pages on our server displaying daily activity for our company. The problem I think is that it sporadically loses its session and redirects back to the login screen to keep losing its session which is the default behavior for anyone on our site trying to access a webpage without being logged in.

I have set the session timeout to 4hrs, the iframe cycles through 6 pages anywhere from 10 seconds to 5 minutes on each, and I have even set the META refresh on the page to refresh every 3 hours. I don't understand what else could possibly stop this page from staying active.

View 3 Replies

Set Timeout On Webservice?

Sep 2, 2010

Setting timeout on a vb.net webservice.

View 2 Replies

.net - Increase The Timeout Period?

Jun 4, 2009

I have to increase timeout period.Following is my code.

Private Function GetConnectionInstance() As SqlConnection
Dim objConn As SqlConnection
Dim strConnection As String
strConnection = ConfigurationSettings.AppSettings("conn")

[code]....

What code i have to add in above to increase timeout period.

View 3 Replies

ADO .NET SqlClient Connection Timeout

Jun 21, 2010

In this situation, my application can connect to the MSSQL server in one of two ways; via a direct TCP/IP connection (WAN) (IP's filtered using RRAS in 2003 Server) or via a VPN connection. The application will first try to open the connection using the WAN connection string and if it can't, then it tries using the VPN connection string. My issue is, I set the connection timeout to 5 seconds for the first attempt but it's taking way longer than that to return an exception. The order in which I attempt to open the connection doesn't really matter. I have looked at the ConnectionTimeout property after changing the connection string and it does indeed show 5 seconds. It appears that the connection timeout value is being ignored.

View 6 Replies

C# - Recaptcha Error In .net - Timeout?

Sep 16, 2011

I am facing error with recaptha, timeout.

I have specify all keys and just valid() calpcha function on code behind.
It waits for while and time out.

More over, When doing page.Isvalid() with capcha, it is alway false, what should be the reason?

<recaptcha:RecaptchaControl ID="recaptcha" Theme="white" runat="server" PublicKey="6LdwMMgSAAAAALdraGklD-N1Jfr5Fuxq6gyaJMy7"
PrivateKey="6LdwMMgSAAAAAKV6hOjAHdFURCUZ6oS_NmxF8iaD" />
recaptcha.Validate();

View 2 Replies

Connection Timeout Expired?

Jul 17, 2009

am using vb.net 2008 and sql server 2008. I have a search form and when i search at times, I have "Connection Timeout Expired" error.I dispose and close the connection after establishment, but i still get it. tried setting MyConObj.ConnectionTimeout = 0 and it also gives me "Property ConnectionTimeout is ReadOnly.

View 1 Replies

Equivalent Of Timeout.bas Module From VB6

Dec 30, 2010

I am looking for the VB.NET code of a very handy little *.bas file I used to use in Visual Basic 6. The file was called timeout.bas and it was the greatest module ever to me. I want to switch to start using VB.NET finally but this single file is holding me back. Trying to use .NET without it is like crippling me. [code]

View 3 Replies

How To Implement Timeout Feature To Use In DLL

Feb 19, 2011

I need to wait for and event within a given period (30s) and then timeout if this time elapse. I am sending a command to a server from a dll, and I need to wait for response before sending another. I want to implement a timeout feature, that why I need to use a timer. I want to use a timer, but don't know how to use it in a DLL.

View 2 Replies

Set Timeout Time For Proxies?

Feb 17, 2009

How to set timeout time for Proxies.

i am using

dim w as new webclient

w.proxy= new system.net.webproxy("xxx.xxx.xxx.xxx.:xxx")

most of the time it says unable to connect or it throws any error msgs... when i check those proxy in internet, they seem to work well. only few proxies are working.

View 2 Replies

Set Timeout To A Query Execution?

Nov 26, 2010

I have the next code that works with AS400

1.- ConexionODBC = New OdbcConnection("dsn=" & gStrDSNIBS & ";uid=" & gStrIdUsuarioDBIBS & ";pwd=" & gStrPasswordDBIBS & ";")
2.- ConexionODBC.Open()
3.- sQuery = "CALL MIFSTORE.SP_TPVFEE1"

[code]....

The purpouse is to execute a SP, but sometimes the DBA modifies the SP without any notification.When the SP is modified and runs the app, the code freezes in the line 7 but does not return a value nor error, even, after 2 hours it remains in that line, I have set the command.timeout (line 6) but it doesn't work either.how to stop the execution of the SP after a period of time.

View 1 Replies

SMTP Timeout Error?

Jun 11, 2011

I am using VB 2010 on a Windows 7 Home Premium PC. I can't get my my smtp code to send an email out. It always comes back with the error:"The operation has timed out"I have both a Google Mail account and a Sky Mail account both of which use the same port but can't get either to work. I have checked my firewall and the smtp port 465 is allowed and I can see the process going through the firewall.I know the mail works fine as I am using Windows Live Mail which sends and receives no problem. The code I am using is below:

Private Sub btnAddAmount_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles btnAddAmount.Click
Dim message As New MailMessage

[code].....

View 1 Replies

Socket.Connect() With A Timeout?

Oct 16, 2009

I'm trying to use a socket to connect a TCP stream. The socket connects no problem if the endpoint has a valid IP associated to it. If I give it an invalid one, the Connect method will sit and block (I want it to) for 10-20 seconds before telling me the remote host timed out. Is there a timeout property I can set so I don't have to wait that long for the connect method? Or is there another way of doing it that does implement a timeout?

View 3 Replies

Sockets And Timeout Errors?

Jan 3, 2011

I'm building a program that has a very basic premise.

For X amount of Objects
Open Conection
Perform Actions

[code].....

View 2 Replies

SQL Bulk Copy Timeout?

Nov 24, 2009

I'm using sqlbulkcopy to load data into a sql2008 database, and we're getting timeout errors loading larger tables. Some tables which were loading OK are failing since indexes have been added to them. The source data is a Informix datareader. I've tried setting large values in both the connection timeout and the sqlbulkcopy.bulkcopytimeout, but the timeout usually occurs within 60 seconds, well below the timeout values I've set (240 secs). I've tried setting the .bulcopytimeout property to zero but it makes no difference. Very occasionally a load will take place - the last large table to load took 7 minutes. I've reduced the batch size to 500.

The documentation on bulkcopytimeout that I have found does not describe what the property actually means - is it the maximum time to complete the entire copy or to complete one batch or what ?Here's some extracts from my error log - the first shows a successful large table load, follow by timeout failures.

24/11/2009 10:59:01
Level : Information
MISLoad - Starting load from Mach4 to ParagonMIS of all selected tables

[code]....

View 7 Replies

SqlException Timeout Expired?

Jun 28, 2011

I am connecting to a vendor-supplied Web Service running in our domain and am attempting to execute one of its methods. I am receiving the error below (Timeout Expired) and not sure how to fix it. The server is running SQL Server 2000 (soon to be upgraded!) and I have checked the timeout setting which is set to 0 (unlimited)

View 4 Replies

Timeout Not Working In SQL Connection

Jun 10, 2010

I have this simple code to test that a DB is ready:
Function testlocalcon() As Boolean
Dim constr As String = _clconstr
Try
Using t As New SqlConnection()
constr = constr & " ; Connect Timeout=1"
[Code] .....
I do not want to execute a query, just to check the connection, but no matter what the time out parameter is ignored.

View 1 Replies

VS 2008 Add A Timeout To Code?

Jun 15, 2012

I found the following code on another site that works great for what I need. Is there any way I can add a timeout in this code? I can't figure how to do it.

[Code]...

View 1 Replies

VS 2010 - Db Timeout When Doing Refresh

Mar 18, 2011

I have a vb10-form that makes connection with a SQL-db. The first time the SQL command is executed perfectly and the records are showed as they should. When I do a refresh (or automatic refresh after 1 min) I get: "Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding" The strange thing is that this only happens on one PC, all the other work.

View 19 Replies







Copyrights 2005-15 www.BigResource.com, All rights reserved